What Do the Error Codes on My OutOfAir ZERO Mean?

The OutOfAir ZERO has five codes. Two of them (HI and E4) you can clear yourself in a few minutes. E3 usually just means the machine is too cold. E1 and E2 mean a sensor has failed and we need to hear from you.

Code What it means What to do
HI The heat strip got too hot Wait a few minutes. It clears by itself.
E1 Temperature sensor fault Contact us
E2 Temperature sensor fault Contact us
E3 The machine is too cold Let it warm up to room temperature
E4 It couldn't pull a vacuum Check the bag, the lid, and the gaskets, then try again

With every code, all of the function lights flash along with the display. That's normal.


HI: overheat protection

You sealed a lot of bags in a row and the heat strip passed 185°F (85°C). The buttons stop working until it cools below 140°F (60°C), then the machine goes back to normal by itself. Nothing is broken. The full story is here: Why Is My ZERO Vacuum Sealer Flashing "HI"?


E4: it couldn't pull a vacuum

The pump ran for 100 seconds and never reached full vacuum. The display flashes E4 five times, then the ZERO goes back to standby so you can try again. Air is getting in somewhere. Usually it's the bag, but a damaged gasket causes it too.

  • Make sure the open end of the bag sits fully inside the vacuum channel. Which side faces up doesn't matter, but the opening has to be in the channel.
  • Smooth out any wrinkles along the open end and pull the bag flat while you close the lid.
  • Check that the lid is closed all the way on both sides.
  • Check the gaskets, the soft seals around the vacuum channel in the lid and in the base. If one is torn, flattened, cracked, or popped out of its groove, air leaks past it and the ZERO can't pull a vacuum.
  • Look the bag over for a puncture, or a bottom seal that didn't take if you cut it from a roll.
  • If you're using the hose, check that it's pushed in at both ends and the canister lid is seated.

If a gasket looks damaged, contact us and we'll get you a replacement. You can also order a top and bottom set here: OutOfAir Zero Vacuum Sealer Replacement Gaskets.

More tips on getting a bag to seal and stay sealed: Vacuum Sealing Tips & Problem Solving.


E3: the machine is too cold

The temperature sensor is reading -4°F (-20°C) or lower, and the buttons are locked out. This usually happens when the ZERO has been sitting in a cold garage, a camper, or a delivery truck in January. Bring it inside, let it sit until it's at room temperature, and try again.


E1 and E2: temperature sensor fault

E1 means the temperature sensor has shorted. E2 means it's disconnected. Either way the ZERO locks its buttons, because it can't seal safely without knowing how hot the heat strip is.

Unplug it, wait a minute, and plug it back in. If the code comes back, there's nothing you can fix at home.

If you see E1 or E2 more than once, or E3 on a machine that's at room temperature, get in touch. The ZERO has a 2-year warranty and we'll take care of you.